Apc Back Ups 600 User Manual

Advertising
  • BX600C-IN - APC Back-UPS 600, 230V without Auto Shutdown Software, India. APC Back-UPS 600, 230V without Auto Shutdown Software, India. User Manual, Warranty card. Standard Lead Time: Usually in Stock. Product Distribution: India. Output; Output Power Capacity: 360 Watts / 600 VA. Max Configurable Power (Watts).
  • Back-UPS ES 400/550/700. As directed by APC Technical Support. For Back-UPS ES 550, order RBC2. For Back-UPS ES 700, order RBC17. Item Specification BE400 BE550 BE700 APC Contact Information The UPS can be mounted vertically or horizontally to a wall surface.
  • Jan 24, 2012  HI All I have a old ups model Back-ups 600 ec, the unit still working fine, but i just notice that when the unit was on battery the LED at the switch is Blinking and the beeping is quit normal, so this Blinking is a by nature for this ups? Thanks in advance.

2018 vw gti owners manual. Back-ups ns 600, Status indicators, Connect. Read online or download PDF. American Power Conversion NS 600 User Manual Manuals Directory ManualsDir.com - online owner manuals. Oct 06, 2016  Home » Spaces » Back-UPS & Surge Protectors » discussion » General » Back-UPS 600 with continous beep Back-UPS 600 with continous beep Discussion in Back-UPS & Surge Protectors started. I've seen similar APC Back-UPS models become 'tripped up' into falsely indicating they have a faulty battery after a large number of frequent small.

Back-UPS NS 600

User’s Guide

1

2

3

Connect Battery

Equipment

Power On and
Install Software

990-2437A Copyright © 2007 American Power Conversion Corp.

All other trademarks are property of their respective owners.

Surge Protection

These outlets provide full-time protection from surges even if the
Back-UPS NS is switched OFF. Plug your printer, fax machine,
scanner, or other peripherals that do not need battery power into
these outlets.

Battery Back-up plus Surge Protection

These outlets are powered whenever the Back-UPS NS is
switched ON. During a power outage or other utility problems
(brownouts, over-voltages), these outlets will be powered for a
limited time by the Back-UPS NS. Plug your computer,
monitor, CD-ROM drive and one other data-sensitive device
such as an external disk or tape drive, or Home Phoneline
Networking Association (HPNA) device into these outlets.

Press the ON/OFF switch to power the unit
ON.

A single short beep and the green “Power”
indicator confirms the Back-UPS NS is on and
ready to provide protection.

The Back-UPS NS should charge for at least 16
hours to ensure sufficient runtime. The unit is
being charged whenever it is connected to utility
power, whether the unit is turned ON or OFF.

If the red Building Wiring Fault indicator (located
on the end near the power cord) is lit, your
building wiring presents a shock hazard that
should be corrected by a qualified electrician.

Install the PowerChute

®

Personal

Edition

software

Place the PowerChute Personal Edition CD-
ROM into your computer and follow the
installation instructions on the screen.

w

w

w.apc.com

®

APC, Back-UPS and PowerChute are registered trademarks of American Power Conversion Corp.

Status

Visual Indicators

Audible Indicators

Alarm Terminates

When

On Line - UPS is supplying conditioned
utility power to the load.

Power LED - ON

None

n/a

On Battery - UPS is supplying battery
power to the load connected to the
Battery outlets.

Power LED - ON
(off during beep)

Beeping 4 times
every 30 seconds

UPS transfers back to
On Line operation, or
when UPS is turned
off.

Low Battery Warning - UPS is supplying
battery power to the load connected to
the Battery outlets and the battery is near
exhaustion.

Power LED - Flashing

Rapid beeping (half-
second intervals)

UPS transfers back to
On Line operation, or
when UPS is turned
off.

Replace Battery - Battery needs to be
checked and/or replaced, or battery is not
connected.

Power LED - Flashing

Constant tone

UPS turned off with
the power switch.

Overload Shutdown - During On Battery
operation a battery power supplied outlet
overload was detected.

Power LED - OFF

Constant tone

UPS turned off with
the power switch.

Sleep Mode - During On Battery
operation the battery power has been
completely exhausted and the UPS is
waiting for utility power to return to
normal.

Power LED - OFF

Beeping once every
4 seconds

Utility power is
restored, or if utility
power is not restored
within 32 seconds, or
the UPS is turned off.

Building Wiring Fault - Your building
wiring presents a shock hazard that
should be corrected by a licensed
electrician.

Building Wiring Fault
LED (red) - ON

None

UPS is unplugged, or
plugged into a
properly wired outlet.

Status Indicators

Power

Circuit

Breaker

AC Line

Cord

Building Wiring

Fault Indicator

UPS Power

Indicator

Power

Switch

®

See the Troubleshooting section for additional assistance.

For safety, the Back-UPS NS is shipped with one battery wire disconnected. The UPS will not operate until the wire is connected to the touch-safe
battery terminal. NOTE: Small sparks may occur during battery connection. This is normal.

Turn the Back-UPS NS over and press in the
two release tabs. Slide the plastic battery
cover off the unit.

Insert the battery back into the compartment.
Slide the plastic battery cover in place until the
two tabs lock into place.

Connect the battery wire firmly to
the battery terminal.

1

2

3

Plastic Battery

Cover

Release Tabs

Battery Wire

Battery Terminal

Connect

Connect Modem / Phone / DSL / Fax / HPNA to Surge Protection

Apc back ups rs 600 user manual

The Back-UPS protects a single line (2-wire) phone (including Digital Subscriber Line -
DSL), Home Phoneline Networking Association (HPNA) type equipment, modem, or
fax machines from surges when connected through the UPS as shown below.

Place the Back-UPS NS to avoid:

- Direct sunlight
- Excessive heat
- Excessive humidity or contact with fluids

Plug the Back-UPS NS power cord directly into a wall outlet; not a surge
protector or power strip.

Connect Computer Cable

The supplied cable and software provide automatic file saving and shutdown of the
operating system in the case of a sustained power outage.

Connect the cable to the Data Port of the Back-UPS NS. Connect the other end of the
cable to the USB port on your computer. The software will automatically find the USB
Port of your computer.

Apc Ups 600 Manual

DSL / MODEM /

WALL

TO COMPUTER USB PORT

FROM WALL JACK

DATALINE OUTPUT TO DSL,

MODEM, PHONE,

OUTLET

DATA PORT

FAX

Power

Battery Backup plus Surge Protection

Surge Protection

The Back-UPS NS indicates operating status
using a combination of visual and audible
indicators.