Gb Instruments Gdt 292a User Manual
Instruction Manuals. GDT-311 Manual 3 Function Multimeter (New Style) manual: GDT-311 Manual 3 Function Multimeter (Old Style). Of the information and data on this site is for informational purposes only and is provided for the convenience of the user. Some information and data on may contain errors or inaccuracies, or there may be. Need user manual for GB GMT-19P Manual for a gardner bender electrical gdt-11 Gardner Bender GB GMT-312 12 Range Pocket Multimeter. GB Instruments GMT-12A, gb instruments gdt-11, gdt-11, gb instruments gdt-11 manual, gdt-11 multimeter manual, gb instruments gdt-11 user manual /pdf/g15m-r-manual-transaxle-disassembly.pdf 2014-11-11. Gb Instruments Gmt-18a User Manual. Bender GDT-3190 4-Function Manual Ranging Digital Multimeter Gardner Bender GB GMT-18A Multimeter, 6 Functions- 14 Range GB Instruments GMT-312 Analog Multimeter Tester 300V 5 Function 12 Range w Leads. We've updated the.
Test Instruments. Testing equipment can be put to good use ensuring that electrical equipment is properly installed and safe to operate. Faulty installations can be lethal; the condition of electrical installations can be established when contractors use test equipment. View and Download GB Instruments GDT-190A owner's manual online. Digital Multimeter. GDT-190A Multimeter pdf manual download.
Gardner Bender’s GDT-11 is a handheld digital multimeter with a 3 1/2-digit liquid crystal numeric display. The meter measures volts for direct and alternating currents, resistance and DC current. In addition, the unit has a diode check feature.
Preparing Meter and Battery
Snap the battery clip onto one of the batteries; set the battery aside for measuring voltage and current.
Plug the red test probe into the meter socket marked VΩmA.
Plug the black test probe into the meter socket marked COM.
Rotate the function selector knob to any setting other than OFF. If the display does not turn on, or if you see the BAT indicator on the display, replace the meter’s internal 9-volt battery with a fresh one.
Tip
Measurements of a 9-volt battery are safe as the voltage is too low to pose a shock hazard.
DC Voltage
Rotate the function selector knob until it points to the 20 range in the DC voltage scale, indicating a maximum of 20 volts. The DC voltage scale is indicated by the V-- symbol on the meter.
Touch the metal tip of the red meter probe to the positive wire of the battery clip; usually this is the red wire. Touch the tip of the black probe to the negative wire, which is black.
Read the voltage indicated on the meter’s LCD display. The meter should measure roughly 9 volts.
Tip
You can measure voltage or current with the probe polarity reversed; however, the meter will display a negative number. This does not adversely affect the meter or the components you’re testing.
Warning
Avoid touching the metal probe tips when measuring voltages greater that 50V; high voltages pose a shock hazard.
Resistance
Rotate the function selector knob until it points to the 200 range on the meter’s resistance scale, indicated by the Ω symbol.
Touch the red meter probe tip to one of the resistor’s leads. Touch the black probe to the remaining resistor lead.
Read the resistance on the meter’s display. You should see a reading of about 100 ohms; a few percent higher or lower is normal.
Warning
- Do not touch the metal probe tips when measuring resistance; the resistance of your skin will affect the meter’s accuracy.
- Do not attempt to measure resistance for circuits or components that are powered on or have currents running through them; you might blow the meter’s fuse or damage the unit.
DC Current
Wrap the positive battery clip wire around one of the leads of the resistor.
Rotate the function selector knob until it points to the 200 range in the meter’s DC current scale, indicated by the A-- symbol.
Touch the tip of the red meter probe to the free lead of the resistor. Touch the tip of the black meter probe to the negative battery clip wire.
Read the current value on the meter’s display. You should see a reading of about 90 milliamps or .09 amps.
Warning
Do not attempt to measure currents in excess of 200 milliamps unless the red meter probe is plugged into the 10A DC socket and the selector knob points to the 10A-- range.
Always measure current with a resistance connected in series with a battery or other power source; the resistance limits the current and avoids a potentially damaging short circuit.
or current than the set range of the
multimeter will allow.
4)
Do not touch the metal
probes of the test leads when making a
measurement.
5) Replace worn test leads. Do not use test
leads with broken or tattered insulation. Only
test leads meeting ETL, cETL, CAT II
300V IA can be used in this multimeter.
6) Discharge a capacitor before measuring it.
7) Remove the test leads from the circuit being
measured as soon as the test is completed.
8)
Do not measure voltage
when the function/range switch is set on
the resistance (ohms) or the current (mA)
settings. Never measure current when the
meter is set on the resistance range.
Never measure AC voltage when the
meter is set on DC voltage or DCmA.
Setting the meter on the incorrect function
may burn out some of the internal circuitry
and may pose a safety hazard.
3. Operating Suggestions
Zeiss Ikon Contaflex Super B printed camera manual. Receive a high quality printed and bound manual in days. 100% guarantee on all orders. If you aren't completely happy just return the manual for a full refund. We have been in business for over 40 years and have hundreds of thousands of satisfied customers all over the world. View and Download ZEISS IKON Contaflex Super instruction book online. Contaflex Super Film Camera pdf manual download. Related Manuals for ZEISS IKON Contaflex Super. Film Camera ZEISS IKON CONTAFLEX III Instruction Book (42 pages) Film Camera ZEISS IKON CONTINA IIA Instructions For Use Manual. 35mm (31 pages). Zeiss ikon Contaflex Super B Pdf User Manuals. View online or download Zeiss ikon Contaflex Super B Instruction Manual. Zeiss Ikon Contaflex Super B Posted 11-12-'06 / 6-24-'18. The next page contains information on this camera. If the image below looks like your camera, click below to see the full manual. ANOTHER VERSION OF THIS MANUAL. Click here for yet another version. Zeiss ikon contaflex super b manual. The only wide- angle R lens that I have is the first generation 35mm f/ 2. If you are looking for Carl Zeiss lens prices, check the Carl Zeiss Lens Price Guide or Carl Zeiss Jena Lens Price Guide. Zeiss ikon contaflex super b user manual.
1) Set the function/range switch to the proper
position before making a measurement.
When the voltage or current is not known, it
MUST be determined that the capacity of
the selected range will handle the amount of
voltage or current in the circuit (see #3
under
For Your Safety). Always start with the
highest range in the function. If the
reading falls within the range of a lower
setting, reset the function/range switch to
!
WARNING
!
WARNING
6
5
the appropriate setting for greater accuracy.
2) Avoid placing the meter in areas where
vibration, dust or dirt are present. Do not
store the meter in excessively hot, humid
or damp places. This meter is a sensitive
measuring device and should be treated
with the same regard as other electrical
and electronic devices.
Gb Instruments Gdt-292a User Manual
3) Using the meter in areas with high magnetic
fields can result in inaccurate readings. For
greatest accuracy, lay the meter flat on a
non-metallic surface.
4) When the meter is not in use, keep the
function/range switch in the OFF position.
This keeps the needle indicator from
deflecting or ”bouncing” excessively.
5) When disconnecting the test leads from
the unit, always grasp the leads where the
input jacks meet the meter housing. Never
pull the leads out of the jacks by the
insulated wire or transport the meter using
the test leads as a carrying strap.
6) Never immerse the meter in water or
solvents. To clean the housing use a damp
cloth with a minimal amount of mild soap.
7) If the resistance (ohms) function of the
meter is not going to be used for a week or
more, remove the internal battery to avoid
potential leaks that may damage the unit.
3.1 Preliminary Adjustments
Fully seat the test leads in the correct input
jacks. If necessary, using a small flat tip
screwdriver, slowly turn the mechanical zero
GMT-312 5-09 manual.qxp 5/21/09 3:04 PM Page 6