Ge Sunsmart Model 32787 Users Manual
GE Appliances' owner's manuals page offers specific use and care guides and installation instructions on GE Appliances as well as Quick Specs and Energy Guides. Enter your appliance's model number to download owner's manuals, use and care manuals, installation information and energy guides.
DST (Daylight Savings Time)
1. To activate DST press both of the “HOUR” and “MIN” keys at the
Jan 13, 2018 How to Program A Defiant Indoor In Wall Digital Timer model 32648 - Instructions The GE SunSmart in-Wall Digital Timer, Push Button, Backlit LCD. Jan 13, 2018 Defiant In Wall Digital Timer Review model 32648 - A simple and easy to use timer. In this video I review the features and specifications of the Defiant in wall, 7 day programmable, daylight. Sep 06, 2012 15312 Initial Setup (part 1 of 5) - GE SunSmart Timer Jasco Products Company. The GE SunSmart Timer also includes a random security feature that varies on. Sep 04, 2012 Watch this video to learn how GE Digital Timers automate lights using easy-to-program preset options or custom time settings. This digital timer uses.
same time. The present time will increase by an hour and the
screen will
show “DST”
2. To de-activate DST press the “HOUR” and “MIN” keys at the same
time. The “DST” will no-longer be on the screen.
Random, on/off Setting:
This feature sets the timer to switch lights ON and OFF at random
intervals while you are out of the house. This function will only
operate if one or more programmed switching commands are set.
1. To activate press the “DAY” and “HOUR” keys at the same time.
Once activated the “TIMER” symbol will be blinking.
2. To de-activate press the “DAY” and “HOUR” keys at the same time
again. The “TIMER” symbol will no longer be on the display.
Reviewing Programs:
1. To review the programs that have been entered, press and release
the “PROG” key. Each time you do this you will be able to scroll
thru the programs.
2. Any program can be edited by pressing the “HOUR”, “MIN”, and
“DAY” keys. Then press the “PROG” key in order to accept the
changes.
3. When complete press the “CLOCK” key to return to current time
and day.
Deleting Programs:
1. To delete a particular program simply press the “PROG” key until
the desired program is displayed.
2. Then press the “HOUR” and “MIN” keys until --:-- is displayed.
Then press the “PROG” key in order to delete this particular
program.
3. When complete press the “CLOCK” key to return to current time
and day.
Electrical Ratings:
120VAC 60Hz
15A Resistive
15A Tungsten
1HP
*When done programming,
close door.
Manual Override:
Pressing the door will override the timer setting and will manually
turn the switch ON and OFF.
NOTE:
When you initially program the unit it may be necessary to press the
manual override key as the unit will not look back to determine if it
should be ON. For example if the current time is 2:00PM and you just
programmed the unit to turn ON at 1:00PM, you will need to press
the manual override key to turn it ON. Thereafter, the unit will resume
normal operation (automatic).
Do not use a metallic object to adjust this timer. Always use a
non-metallic object such as a wooden pencil.
MEMORY BACK UP:
This timer is equipped with a rechargeable Ni-Mh battery which will
protect your programs during power failure for up to 30 days.
No need to replace battery.
Note that the screen blanks if the battery is discharged completely.
is a trademark of the General Electric Company and is used
under license to Jasco Products Company LLC, 10 E. Memorial Road,
Oklahoma City, OK 73114.
This Jasco product comes with a 1 year limited warranty.
Visit www.jascoproducts.com for details.
Smart Digital Timer
Installation Instruction
1. Turn OFF the main power at the circuit breaker.
2. Remove the existing switch.
3. Connect the wires of Timer and wall box as followed by using the wire
nuts provided.
a) Connect the Hot/Live wire of main power to the Black wire from Timer.
b) Connect the Neutral wires to the White wire from Timer. Often, the
neutral wire can be found in the back of the wiring box bound in a
wire nut.
c) Connect the Hot/Live wire of Load to the Red wire from Timer.
d) Connect the Ground wire to the Green wire from Timer.
Note: Be sure that all wire nuts are secure.
4. Tuck the wires into the wall box leaving room for the Timer. Using the
screws provided, mount the timer to the wall box being careful not to
crush any wires.
5. Place wall-plate over timer and screw in to place using screws provided
6. Turn Main power ON
POWER-UP SEQUENCE:
1. Lift up the bottom of the door using a small slotted screwdriver.
2. Position the slide switch to TIMER.
3. Press the “RESET” button using an insulated tool such as a toothpick.
4. The display should flash 12:00AM on Monday.
Setting Current Time:
1. Press and HOLD the “CLOCK” key during this entire procedure.
2. Press the “HOUR” key to advance the hours.
3. Press the “MIN” key to advance the minutes.
4. Press the “DAY” key to advance the day.
5. If any keys are pressed for a prolonged period, the display will
advance rapidly.
6. Release the “CLOCK” key once the time and day have been entered. Now
the timer is in operation and ready to be programmed. The colon “:” after
the hours will continuously flash indicating that the clock is running.
Programming ON/OFF Events:
1. Press the “PROG” key once. TIMER 1 on - - : - - appears.
2. Using the “HOUR” and “MIN” keys enter the desired ON time. See block
programming below for selecting different days of the week.
When complete press the “PROG” key once.
3. Timer OFF --:-- will be displayed. Using the “HOUR” and “MIN” keys
enter the desired OFF time. See block programming below for selecting
different days of the week. When complete press the “PROG” key once.
4. If complete press the “CLOCK” key to return to current time
and day.
5. Note that a total of 7-ON and 7-OFF events can be programmed.
Block Programming:
1. When programming ON/OFF events, all days are indicated by default.
To change the day selection simply keep pressing the “DAY” key and the
display will change as follows:
Ge Sunsmart Digital Timer Instructions
a) Monday - Sunday (Default)
b) Individual Days (Only select 1 day)
c) Monday - Friday
d) Saturday and Sunday
e) Monday - Saturday (Off Sunday)
f) MO, WE, FR
g) TU, TR SA
h) MO, TU, WE
i) TR, FR, SA
15071
= Wiring Nut
Typical Wiring Schematic
Black
Black
Light
White
White
White
Red
Green
Ground
Timer
120 VAC
Power
Source
LOAD
LINE
GROUND
TIMER-GREEN
WALL-BARE
NEUTRAL
[WHITE]
LINE
[BLACK]
LOAD
TIMER-RED
WALL-BLACK
15071
Manual Version 2
01-24-2010
www.jascoproducts.com
If you are unsure or unclear about this instalation, contact a qualified
licensed electrician.
Programming On/Off Events: (up to 4 ON/OFF program)
1. Push “Setup/PGM” twice. “P1” will flash on screen.
2. Push + or - to choose the desired program to change, or start at “P1 ON.”
Push enter to confirm which program P1, P2, P3, or P4 you are setting.
3. Push + or - to choose between “set” or “del” program. Push enter to confirm.
4. Push + or - to choose the desired days you would like the timer to activate.
The options are;
• S, M, T, W, Th, F, S (All days)
• S, S (Weekend)
• M, T, W, Th, F (Weekdays)
• M through S: (Individual days)
• T, Th
• M, W, F
Push enter to confirm the days of week setting.
5. Push + or - to choose the desired hour. Push enter to confirm.
6. Push + or - to choose the desired minute. Push enter to confirm.
7. After completion of steps 1 to 6 the ON time and days selected are
complete. Repeat steps 4 to 6 to set the OFF time for the program.
8. Once ON and OFF for a program is chosen the timer will ask you to “save”
- push enter to save program, then continue to set other programs. When
finished programming push Setup.
Note: The display will show “AUTO” to alert you a program is running.
*When done programming, close door. You cannot exit during a program cycle.
Using Random Feature: The random feature will turn lights on and off using
the programmed times + or - 30 minutes. This gives your house a more lived in
appearance.
1. Push the random button to activate random feature. The screen will change
from “AUTO” to random. Screen will display “RDM”
2. Push the auto button to deactivate random mode. Screen will display “AUTO”
Ratings:
120VAC 60Hz
Incandescent (Tungsten): 5A/600W
Resistive: 15A/600W
Maximum Temperature: 40°C
Manual Override:
Manual override will not effect programing.
Pressing the door will override the timer
setting and will manually turn the switch ON
and OFF.
Memory Back Up: This timer is equipped
with memory back up that will protect the
settings for up to 60 minutes. You never have
to replace batteries. The internal backup
requires about 12 hours to fully charge.
ON - OFF Slide Switch: Turns power to the
timer ON or OFF. In “OFF” position timer will
not function manually or automatically.
ON = Power to timer & fixture.
OFF = No power to timer or fixture.
For normal operation leave in the on
position.
Digital Timer
If you are unsure or unclear about this installation, contact
a qualified licensed electrician. Not for use with CFL or
fluorescent bulbs. Use with incandescent, xenon, halogen.
Aug 01, 2019 The Agilent 7800 ICP-MS is an easy to use robust quadrupole inductively coupled plasma - mass spectrometer (ICP-MS) designed to simplify routine ICP-MS analysis. With high matrix tolerance, wide dynamic range, and effective control of polyatomic interferences using helium mode with kinetic energy discrimination (KED). It takes the uncertainty out of analyzing. Agilent 7800 icp-ms operator manual.
Safety ground (green) must be connected for proper
operation.
Installation Instruction
1. Turn OFF the main power at the circuit breaker.
2. Remove the existing switch.
3. Connect the wires of the timer to the wall box as shown in
Figure 1 and
Figure 2 using the wire nuts provided.
a) Connect the line wire to the black wire from Timer.
b) Connect the load wire to the blue wire from Timer.
c) Connect the ground wire to the green wire from Timer.
Note: Be sure that all wire nuts are secure.
4. Tuck the wires into the wall box leaving room for the timer. Using the screws
provided, mount the timer to the wall box being careful not to crush any
wires.
5. Turn main power ON at the circuit breaker.
POWER-UP SEQUENCE: If you don’t see the numbers on the screen you will
want to verify the unit is wired correctly, the unit is getting power, and the bulb
in the fixture is good.
Verify the Power slide switch inside the button is set to the ON position. See
Figure 3.
Note: If the timer has no display check the bulb first to make sure the light bulb
is screwed in tight and not burned out. A working light bulb must be installed
to complete the circuit.
1. Open the door by inserting a fingernail or screwdriver in the space provided
at the top of the door and pulling forward. See
Figure 4.
2. Position the Power switch to ON (To Right Side). Display will not appear until
switch is on. See
Figure 3.
3. Push and hold the RESET button for 3 seconds. The word Reset will appear
on the screen.
NOTE: When adjusting settings on timer, always use a non-
metallic, insulated tool such as a toothpick or wooden pencil.
4. The display should flash 12:00 am.
Setting Current Day & Time:
1. Push Setup/PGM once, date will appear on screen.
2. Push the + or - to move the arrow under the current day of the week (S, M, T,
W, T, F, S). Press enter to confirm. See
Figure 5. Hour will appear on screen.
3. Push the + or - to scroll through the Hours. Press enter when the correct
hour is found, minutes will appear on screen. Press the + or - to scroll
through the minutes. Press enter when the correct minute is found to
confirm setting. Be sure (AM/PM) is correct. This is located in the lower left
portion of the display.
15313
03-10-2011
www.jascoproducts.com
Typical Wiring Schematic
Black
Black
Load
White
White
Blue
Line
= Wiring Nut
Ground
Green
Timer
Figure 1
Figure 3
Figure 4
Figure 5
Figure 2
Green
Blue
(Load)
Black
(Line)
Black
Black
Ground